Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.987
Filtrar
1.
Catheter Cardiovasc Interv ; 103(6): 885-896, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38566527

RESUMO

BACKGROUND: Two invasive methods are available to estimate microvascular resistance: bolus and continuous thermodilution. Comparative studies have revealed a lack of concordance between measurements of microvascular resistance obtained through these techniques. AIMS: This study aimed to examine the influence of vessel volume on bolus thermodilution measurements. METHODS: We prospectively included patients with angina with non-obstructive coronary arteries (ANOCA) undergoing bolus and continuous thermodilution assessments. All patients underwent coronary CT angiography to extract vessel volume. Coronary microvascular dysfunction was defined as coronary flow reserve (CFR) < 2.0. Measurements of absolute microvascular resistance (in Woods units) and index of microvascular resistance (IMR) were compared before and after volumetric adjustment. RESULTS: Overall, 94 patients with ANOCA were included in this study. The mean age was 64.7 ± 10.8 years, 48% were female, and 19% had diabetes. The prevalence of CMD was 16% based on bolus thermodilution, while continuous thermodilution yielded a prevalence of 27% (Cohen's Kappa 0.44, 95% CI 0.23-0.65). There was no correlation in microvascular resistance between techniques (r = 0.17, 95% CI -0.04 to 0.36, p = 0.104). The adjustment of IMR by vessel volume significantly increased the agreement with absolute microvascular resistance derived from continuous thermodilution (r = 0.48, 95% CI 0.31-0.63, p < 0.001). CONCLUSIONS: In patients with ANOCA, invasive methods based on coronary thermodilution yielded conflicting results for the assessment of CMD. Adjusting IMR with vessel volume improved the agreement with continuous thermodilution for the assessment of microvascular resistance. These findings strongly suggest the importance of considering vessel volume when interpreting bolus thermodilution assessment.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Circulação Coronária , Vasos Coronários , Microcirculação , Valor Preditivo dos Testes , Termodiluição , Resistência Vascular , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Vasos Coronários/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/diagnóstico por imagem , Reprodutibilidade dos Testes
3.
J Am Coll Cardiol ; 83(6): 699-709, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38325996

RESUMO

Diagnosing coronary microvascular dysfunction remains challenging, primarily due to the lack of direct measurements of absolute coronary blood flow (Q) and microvascular resistance (Rµ). However, there has been recent progress with the development and validation of continuous intracoronary thermodilution, which offers a simplified and validated approach for clinical use. This technique enables direct quantification of Q and Rµ, leading to precise and accurate evaluation of the coronary microcirculation. To ensure consistent and reliable results, it is crucial to follow a standardized protocol when performing continuous intracoronary thermodilution measurements. This document aims to summarize the principles of thermodilution-derived absolute coronary flow measurements and propose a standardized method for conducting these assessments. The proposed standardization serves as a guide to ensure the best practice of the method, enhancing the clinical assessment of the coronary microcirculation.


Assuntos
Circulação Coronária , Isquemia Miocárdica , Humanos , Circulação Coronária/fisiologia , Resistência Vascular/fisiologia , Termodiluição/métodos , Hemodinâmica , Microcirculação/fisiologia , Vasos Coronários
4.
Am J Vet Res ; 85(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38335725

RESUMO

OBJECTIVE: To assess the agreement between cardiac output (CO) estimated via evaluation of the arterial pressure waveform by a novel monitoring system (Edwards Acumen IQ sensor and HemoSphere Advanced Monitor Platform [HS-IQ]; Edwards LifeSciences) and measured by thermodilution (TD) in anesthetized, normovolemic, and hypovolemic dogs. To assess the agreement between the HS-IQ CO measurements in the radial artery and dorsal metatarsal artery. ANIMALS: 8 purpose-bred Beagles. METHODS: Dogs were placed under general anesthesia. CO was measured via TD and via the HS-IQ at radial and dorsal metatarsal arterial catheters. CO measurements were obtained at 4 time points including normovolemic and multiple hypovolemic states. Paired measurements of CO were evaluated via the method of Bland and Altman with acceptable limits of agreement (LOA) defined as < 30%. RESULTS: A total of 24 (dorsal metatarsal) and 21 (radial) paired measurements were collected in 8 dogs. The overall bias (CI) for comparison of TD to radial arterial HS-IQ CO measurements was -0.09 L/min. LOA and proportional LOA were -2.66 to 2.49 L/min and -140.72% to 104.94%. The overall bias (CI) for comparison of TD to dorsal metatarsal arterial HS-IQ CO measurements was -0.26 L/min. LOA and proportional LOA were -2.76 to 2.24 L/min and -135.96% to 93.25%. The overall proportional error for radial arterial was -17.9% and for dorsal metatarsal was -21.4%. CLINICAL RELEVANCE: CO measurements with the HS-IQ were easy to obtain but did not produce results within a clinically acceptable range for either measurement site, with a very wide LOA. The CO estimations from the HS-IQ are not appropriate for clinical use at this time.


Assuntos
Doenças do Cão , Termodiluição , Cães , Animais , Termodiluição/veterinária , Termodiluição/métodos , Hipovolemia/veterinária , Monitorização Intraoperatória/métodos , Monitorização Intraoperatória/veterinária , Débito Cardíaco , Artérias , Cateteres de Demora , Reprodutibilidade dos Testes , Doenças do Cão/diagnóstico
5.
J Clin Monit Comput ; 38(1): 139-146, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37458916

RESUMO

PURPOSE: Pulse Decomposition Analysis (PDA) uses integration of the systolic area of a distally transmitted aortic pulse as well as arterial stiffness estimates to compute cardiac output. We sought to assess agreement of cardiac output (CO) estimation between continuous pulmonary artery catheter (PAC) guided thermodilution (CO-CCO) and a wireless, wearable noninvasive device, (Vitalstream, Caretaker Medical, Charlottesville, VA), that utilizes the Pulse Decomposition Analysis (CO-PDA) method in postoperative cardiac surgery patients in the intensive care unit. METHODS: CO-CCO measurements were compared with post processed CO-PDA measurements in prospectively enrolled adult cardiac surgical intensive care unit patients. Uncalibrated CO-PDA values were compared for accuracy with CO-CCO via a Bland-Altman analysis considering repeated measurements and a concordance analysis with a 10% exclusion zone. RESULTS: 259.7 h of monitoring data from 41 patients matching 15,583 data points were analyzed. Mean CO-CCO was 5.55 L/min, while mean values for the CO-PDA were 5.73 L/min (mean of differences +- SD 0.79 ± 1.11 L/min; limits of agreement - 1.43 to 3.01 L/min), with a percentage error of 37.5%. CO-CCO correlation with CO-PDA was moderate (0.54) and concordance was 0.83. CONCLUSION: Compared with the CO-CCO Swan-Ganz, cardiac output measurements obtained using the CO-PDA were not interchangeable when using a 30% threshold. These preliminary results were within the 45% limits for minimally invasive devices, and pending further robust trials, the CO-PDA offers a noninvasive, wireless solution to complement and extend hemodynamic monitoring within and outside the ICU.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Artéria Pulmonar , Adulto , Humanos , Termodiluição/métodos , Débito Cardíaco , Cateterismo de Swan-Ganz , Procedimentos Cirúrgicos Cardíacos/métodos , Cuidados Críticos , Unidades de Terapia Intensiva , Reprodutibilidade dos Testes
6.
Herz ; 49(1): 50-59, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37439804

RESUMO

BACKGROUND: Invasive cardiac output (CO) is measured with the thermodilution (TD) or the indirect Fick method (iFM) in right heart catheterization (RHC). The iFM estimates CO using approximation formulas for oxygen consumption ([Formula: see text]O2), but there are significant discrepancies (> 20%) between both methods. Although regularly applied, the formula proposed by Krakau has not been validated. We compared the CO discrepancies between the Krakau formula with the reference (TD) and three established formulas and investigated whether alterations assessed in cardiac magnetic resonance imaging (CMR) determined the extent of the deviations. METHODS: This retrospective study included 188 patients aged 63 ± 14 years (30% women) receiving both CMR and RHC. The CO was measured with TD or with the iFM using the formulas by Krakau, LaFarge, Dehmer, and Bergstra for [Formula: see text]O2 estimation (iFM-K/-L/-D/-B). Percentage errors were calculated as twice the standard deviation of the difference between two CO methods divided by their means; a cut-off of < 30% was regarded as acceptable. The iFM and TD-derived CO ratio was built, and deviations > 20% were counted. Logistic regression analyses were performed to identify determinants of a deviation of > 20%. RESULTS: The TD-derived CO (5.5 ± 1.7 L/min) was significantly different from all iFM (K: 4.8 ± 1.6, L: 4.3 ± 1.6; D: 4.8 ± 1.5 L/min; B: 5.4 ± 1.8 L/min all p < 0.05). The iFM-K-CO differed from all methods (p < 0.001) except iFM­D (p = 0.19). Percentage errors between TD-CO and iFM-K/-L/-D/-B were all beyond the acceptance limit (44/45/44/43%), while percentage errors between iFM­K and other iFM were all < 16%. None of the parameters measured in CMR was predictive of a discrepancy of > 20% between both methods. CONCLUSION: The Krakau formula was comparable to other iFM in estimating CO levels, but none showed satisfactory agreement with the TD method. Improved derivation cohorts for [Formula: see text]O2 estimation are needed that better reflect today's patients undergoing RHC.


Assuntos
Cateterismo Cardíaco , Termodiluição , Humanos , Feminino , Masculino , Estudos Retrospectivos , Débito Cardíaco , Consumo de Oxigênio
7.
J Anesth ; 38(1): 1-9, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37740733

RESUMO

PURPOSE: Several technical aspects of the Fick method limit its use intraoperatively. A data-driven modification of the Fick method may enable its use in intraoperative settings. METHODS: This two-center retrospective observational study included 57 (28 and 29 in each center) patients who underwent off-pump coronary artery bypass graft (OPCAB) surgery. Intraoperative recordings of physiological data were obtained and divided into training and test datasets. The Fick equation was used to calculate cardiac output (CO-Fick) using ventilator-determined variables, intraoperative hemoglobin level, and SvO2, with continuous thermodilution cardiac output (CCO) used as a reference. A modification CO-Fick was derived and validated: CO-Fick-AD, which adjusts the denominator of the original equation. RESULTS: Increased deviation between CO-Fick and CCO was observed when oxygen extraction was low. The root mean square error of CO-Fick was decreased from 6.07 L/min to 0.70 L/min after the modification. CO-Fick-AD showed a mean bias of 0.17 (95% CI 0.00-0.34) L/min, with a 36.4% (95% CI 30.6-44.4%) error. The concordance rates of CO-Fick-AD ranged from 73.3 to 87.1% depending on the time interval and exclusion zone. CONCLUSIONS: The original Fick method is not reliable when oxygen extraction is low, but a modification using data-driven approach could enable continuous estimation of cardiac output during the dynamic intraoperative period with minimal bias. However, further improvements in precision and trending ability are needed.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea , Humanos , Débito Cardíaco/fisiologia , Monitorização Fisiológica , Consumo de Oxigênio , Oxigênio , Termodiluição/métodos
8.
Anesthesiology ; 140(5): 1002-1015, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38157435

RESUMO

BACKGROUND: Thermodilution is unreliable in veno-venous extracorporeal membrane oxygenation (VV-ECMO). Systemic oxygenation depends on recirculation fractions and ratios of extracorporeal membrane oxygenation (ECMO) flow to cardiac output. In a prospective in vitro simulation, this study assessed the diagnostic accuracy of a modified thermodilution technique for recirculation and cardiac output. The hypothesis was that this method provided clinically acceptable precision and accuracy for cardiac output and recirculation. METHODS: Two ECMO circuits ran in parallel: one representing a VV-ECMO and the second representing native heart, lung, and circulation. Both circuits shared the right atrium. Extra limbs for recirculation and pulmonary shunt were added. This study simulated ECMO flows from 1 to 2.5 l/min and cardiac outputs from 2.5 to 3.5 l/min with recirculation fractions (0 to 80%) and pulmonary shunts. Thermistors in both ECMO limbs and the pulmonary artery measured the temperature changes induced by cold bolus injections into the arterial ECMO limb. Recirculation fractions were calculated from the ratio of the areas under the temperature curve (AUCs) in the ECMO limbs and from partitioning of the bolus volume (flow based). With known partitioning of bolus volumes between ECMO and pulmonary artery, cardiac output was calculated. High-precision ultrasonic flow probes served as reference for Bland-Altman plots and linear mixed-effect models. RESULTS: Accuracy and precision for both the recirculation fraction based on AUC (bias, -5.4%; limits of agreement, -18.6 to 7.9%) and flow based (bias, -5.9%; limits of agreement, -18.8 to 7.0%) are clinically acceptable. Calculated cardiac output for all recirculation fractions was accurate but imprecise (RecirculationAUC: bias 0.56 l/min; limits of agreement, -2.27 to 3.4 l/min; and RecirculationFLOW: bias 0.48 l/min; limits of agreement, -2.22 to 3.19 l/min). Recirculation fraction increased bias and decreased precision. CONCLUSIONS: Adapted thermodilution for VV-ECMO allows simultaneous measurement of recirculation fraction and cardiac output and may help optimize patient management with severe respiratory failure.


Assuntos
Oxigenação por Membrana Extracorpórea , Humanos , Oxigenação por Membrana Extracorpórea/métodos , Termodiluição/métodos , Estudos Prospectivos , Débito Cardíaco , Pulmão
9.
JACC Cardiovasc Interv ; 16(22): 2767-2777, 2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-38030361

RESUMO

BACKGROUND: Coronary flow reserve (CFR) and microvascular resistance reserve (MRR) can, in principle, be derived by any method assessing coronary flow. OBJECTIVES: The aim of this study was to compare CFR and MRR as derived by continuous (CFRcont and MRRcont) and bolus thermodilution (CFRbolus and MRRbolus). METHODS: A total of 175 patients with chest pain and nonobstructive coronary artery disease were studied. Bolus and continuous thermodilution measurements were performed in the left anterior descending coronary artery. MRR was calculated as the ratio of CFR to fractional flow reserve and corrected for changes in systemic pressure. In 102 patients, bolus and continuous thermodilution measurements were performed in duplicate to assess test-retest reliability. RESULTS: Mean CFRbolus was higher than CFRcont (3.47 ± 1.42 and 2.67 ± 0.81 [P < 0.001], mean difference 0.80, upper limit of agreement 3.92, lower limit of agreement -2.32). Mean MRRbolus was also higher than MRRcont (4.40 ± 1.99 and 3.22 ± 1.02 [P < 0.001], mean difference 1.2, upper limit of agreement 5.08, lower limit of agreement -2.71). The correlation between CFR and MRR values obtained using both methods was significant but weak (CFR, r = 0.28 [95% CI: 0.14-0.41]; MRR, r = 0.26 [95% CI: 0.16-0.39]; P < 0.001 for both). The precision of both CFR and MRR was higher when assessed using continuous thermodilution compared with bolus thermodilution (repeatability coefficients of 0.89 and 2.79 for CFRcont and CFRbolus, respectively, and 1.01 and 3.05 for MRRcont and MRRbolus, respectively). CONCLUSIONS: Compared with bolus thermodilution, continuous thermodilution yields lower values of CFR and MRR accompanied by an almost 3-fold reduction of the variability in the measured results.


Assuntos
Circulação Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Termodiluição/métodos , Reprodutibilidade dos Testes , Resultado do Tratamento , Vasos Coronários , Microcirculação
12.
BMC Anesthesiol ; 23(1): 359, 2023 11 04.
Artigo em Inglês | MEDLINE | ID: mdl-37924013

RESUMO

BACKGROUND: Based on the controversy surrounding pulmonary artery catheterization (PAC) in surgical patients, we investigated the interchangeability of cardiac index (CI) and systemic vascular resistance (SVR) measurements between ClearSight™ and PAC during living-donor liver transplantation (LDLT). METHODS: This prospective study included consecutively selected LDLT patients. ClearSight™-based CI and SVR measurements were compared with those from PAC at seven LDLT-stage time points. ClearSight™-based systolic (SAP), mean (MAP), and diastolic (DAP) arterial pressures were also compared with those from femoral arterial catheterization (FAC). For the comparison and analysis of ClearSight™ and the reference method, Bland-Altman analysis was used to analyze accuracy while polar and four-quadrant plots were used to analyze the trending ability. RESULTS: From 27 patients, 189 pairs of ClearSight™ and reference values were analyzed. The CI and SVR performance errors (PEs) exhibited poor accuracy between the two methods (51.52 and 51.73%, respectively) in the Bland-Altman analysis. CI and SVR also exhibited unacceptable trending abilities in both the polar and four-quadrant plot analyses. SAP, MAP, and DAP PEs between the two methods displayed favorable accuracy (24.28, 21.18, and 26.26%, respectively). SAP and MAP exhibited acceptable trending ability in the four-quadrant plot between the two methods, but not in the polar plot analyses. CONCLUSIONS: During LDLT, CI and SVR demonstrated poor interchangeability, while SAP and MAP exhibited acceptable interchangeability between ClearSight™ and FAC.


Assuntos
Transplante de Fígado , Humanos , Transplante de Fígado/métodos , Estudos Prospectivos , Débito Cardíaco , Doadores Vivos , Resistência Vascular , Termodiluição/métodos , Reprodutibilidade dos Testes
14.
Br J Anaesth ; 131(6): 971-974, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37714751

RESUMO

Flow-directed, balloon-tipped pulmonary artery catheters allow measuring cardiac output and other haemodynamic variables including intracardiac pressures. We propose classifying pulmonary artery catheters by generations and specifying additional measurement modalities. Based on the method used to measure cardiac output, pulmonary artery catheters can be classified into three generations: first-generation using intermittent pulmonary artery thermodilution; second-generation using a thermal filament for automated pulmonary artery thermodilution; and third-generation combining thermal filament-based automated pulmonary artery thermodilution and pulmonary artery pulse wave analysis. Each of these pulmonary artery catheter generations can include additional measurements, such as continuous mixed venous oxygen saturation, right ventricular ejection fraction and end-diastolic volume, and right ventricular pressure. This classification should help define indications for pulmonary artery catheters in clinical practice and research.


Assuntos
Artéria Pulmonar , Função Ventricular Direita , Humanos , Volume Sistólico , Cateterismo de Swan-Ganz , Débito Cardíaco , Termodiluição/métodos , Cateteres
16.
J Am Heart Assoc ; 12(16): e030480, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37577948

RESUMO

Background Coronary flow reserve (CFR) and microvascular resistance reserve (MRR) are physiological parameters to assess coronary microvascular dysfunction. CFR and MRR can be assessed using bolus or continuous thermodilution, and the correlation between these methods has not been clarified. Furthermore, their association with angina and quality of life is unknown. Methods and Results In total, 246 consecutive patients with angina and nonobstructive coronary arteries from the multicenter Netherlands Registry of Invasive Coronary Vasomotor Function Testing (NL-CFT) were investigated. The 36-item Short Form Health Survey Quality of Life and Seattle Angina questionnaires were completed by 153 patients before the invasive measurements. CFR and MRR were measured consecutively with bolus and continuous thermodilution. Mean continuous thermodilution-derived coronary flow reserve (CFRabs) was significantly lower than mean bolus thermodilution-derived coronary flow reserve (CFRbolus) (2.6±1.0 versus 3.5±1.8; P<0.001), with a modest correlation (ρ=0.305; P<0.001). Mean continuous thermodilution-derived microvascular resistance reserve (MRRabs) was also significantly lower than mean bolus thermodilution-derived MRR (MRRbolus) (3.1±1.1 versus 4.2±2.5; P<0.001), with a weak correlation (ρ=0.280; P<0.001). CFRbolus and MRRbolus showed no correlation with any of the angina and quality of life domains, whereas CFRabs and MRRabs showed a significant correlation with physical limitation (P=0.005, P=0.009, respectively) and health (P=0.026, P=0.012). In a subanalysis in patients in whom spasm was excluded, the correlation further improved (MRRabs versus physical limitation: ρ=0.363; P=0.041, MRRabs versus physical health: ρ=0.482; P=0.004). No association with angina frequency and stability was found. Conclusions Absolute flow measurements using continuous thermodilution to calculate CFRabs and MRRabs weakly correlate with, and are lower than, the surrogates CFRbolus and MRRbolus. Absolute flow parameters showed a relationship with physical complaints. No relationship with angina frequency and stability was found.


Assuntos
Qualidade de Vida , Termodiluição , Humanos , Termodiluição/métodos , Circulação Coronária/fisiologia , Angina Pectoris/diagnóstico , Coração , Vasos Coronários , Microcirculação/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...